Product Details:
Place of Origin: Shanghai, China (Mainland)
Brand Name: Lanry
Certification: CE
Model Number: TF1100-EI
Payment & Shipping Terms:
Minimum Order Quantity: 1 Unit
Price: Negotiable
Packaging Details: Carton Packing
Supply Ability: 100unit/week
Contact Now
Detailed Product Description
Product Name: Inserted Type Ultrasonic Flow Meter Output: Datalogger/4-20mA /OCT /RS485/RS232/GPRS
Accuracy: Reading+/- 1% Transducer Range: DN20-DN6000
Application: Measuring Liquids Power Supply: 85~265VAC
High Light:

ultrasonic liquid flow meter

,

non invasive ultrasonic flow meter

Insertion type ultrasonic flow meter TF1100-EI for waste water industry
 
Insertion type ultrasonic flow meter TF1100-EI is widly used in many fileds, such as water and waste water industry - hot water, cooling water, potable water, sea water etc., chemical industry, petrochemical industry and so on.
Insertion type ultrasonic flow meter TF1100-EI provides abundant capabilities for accurate liquid flow measurement from outside of a pipe. It utilizes state-of-the-art technologies on ultrasonic transmission /receiving, digital signal processing and transit-time measurement. The proprietary signal quality tracking and self-adapting technologies allow system to optimally adapt to different pipe materials automatically. Due to hot-tapped mounting of insertion transducers, there is no ultrasonic compound and coupling problem; Even though the transducers are inserted into pipe wall, they do not intrude into the flow, thus, do not generate disturbance or pressure drop to the flow. The insertion (wetted) type has the advantage of long-term stability and better accuracy.
 
Insertion type ultrasonic flow meter TF1100-EI for waste water industry Features:
 
1. Hot-tapped installation, no pipe line flow interrupted
2. Thermal energy measurement capability can be optional.
3. Wide bi-directional flow range of 0.01 m/s to 12 m/s..
4. Wide liquid temperature range: -35℃~200℃.
5. For commonly used pipe materials and diameters from 20mm to over 6.0m.

6. Data logger function for insertion ultrasonic flow meter

 

Application
 

General
● Service and maintenance

● Energy efficiency audits

● Replacement of defective devices

● Support of commissioning process and installation

● Performance and efficiency measurement
- Evaluation and assessments
- Capacity measurement of pumps
- Monitoring of regulating valves

 

Water and waste water industry - hot water, cooling water, potable water, sea water etc.)
Petrochemical industry

Refrigeration and air conditioning systems
Food , beverage and pharmaceutical industry

Metallurgy and mining applications

Chemical industry -chlorine, alcohol, acids, .thermal oils.etc
Power supply- nuclear power plants, thermal & hydropower plants), heat energy boiler feed water.etc
Mechanical engineering and plant engineering-pipeline leak detection, inspection, tracking and collection.

 
Insertion Type Transit Time Ultrasonic Flow Meter For Waste Water Industry 0
 

Specifications:Transmitter

 

Measurement principle Ultrasonic transit-time difference correlation principle
Flow velocity range 0.01 to 12 m/s, bi-directional
Resolution 0.25mm/s
Repeatability 0.2% of reading
Accuracy ±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s
Response time 0.5s
Sensitivity 0.003m/s
Damping of displayed value 0-99s(selectable by user)
Liquid Types Supported both clean and somewhat dirty liquids with turbidity <10000 ppm
Power Supply AC: 85-265V DC: 24V/500mA
Enclosure type Wall-mounted
Degree of protection IP66 according to EN60529
Operating temperature -20℃ to +60℃
Housing material Fiberglass
Display 4 line×16 English letters LCD graphic display, backlit
Units User Configured (English and Metric)
Rate Rate and Velocity Display
Totalized gallons, ft³, barrels, lbs, liters, m³,kg
Thermal energy unit GJ,KWh can be optional
Communication 4~20mA(accuracy 0.1%),Frequency(1-9999Hz), Relay, RS232, RS485 (Modbus),Logged data

 

Specifications:Transducer

 

Degree of protection IP67 or IP68 according to EN60529
Suited Liquid Temperature Std. Temp.: -35℃~85℃
High Temp.: -35℃~150℃
Pipe diameter range DN65-6000
Transducer Size Type S Φ58*199mm
Material of transducer Stainless Steel
Cable Length Std: 10m
Temperature Sensor

Pt1000, 0 to 200℃, Clamp-on and Insertion type Accuracy: ±0.1%

 

 

Packing & Delivery

 

Inserted Type Ultrasonic Flow Meter With 4-20mA Output for clean liquid application

 

With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support. With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support.
 
Insertion Type Transit Time Ultrasonic Flow Meter For Waste Water Industry 1Insertion Type Transit Time Ultrasonic Flow Meter For Waste Water Industry 2
Insertion Type Transit Time Ultrasonic Flow Meter For Waste Water Industry 3Insertion Type Transit Time Ultrasonic Flow Meter For Waste Water Industry 4

Delivery

Inserted Type Ultrasonic Flow Meter With 4-20mA Output 

Standard meter: 3-7 days

Special meter: pls contact us

Express, by air, by sea can be optional.

Contact Details
Lanry Instruments (Shanghai) Co., Ltd.

Contact Person: Ms. Tracy Xu

Tel: 86-021-67618991

Fax: 86-021-67801625

Send your inquiry directly to us (0 / 3000)

Other Products