Lanry Instruments (Shanghai) Co., Ltd.

Lanry Instruments (Shanghai) Co., Ltd.

 

Specialize In Ultrasonic Flowmeter More Than 20 Years!

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsTransit Time Ultrasonic Flow Meter

High Accuracy Transit Time Ultrasonic Flow Meter , Insertion Ultrasonic Flow Meter

High Accuracy Transit Time Ultrasonic Flow Meter , Insertion Ultrasonic Flow Meter

  • High Accuracy Transit Time Ultrasonic Flow Meter , Insertion Ultrasonic Flow Meter
High Accuracy Transit Time Ultrasonic Flow Meter , Insertion Ultrasonic Flow Meter
Product Details:
Place of Origin: Shanghai, China (Mainland)
Brand Name: Lanry
Certification: CE
Model Number: TF1100-EI
Payment & Shipping Terms:
Minimum Order Quantity: 1 Unit
Price: Negotiable
Packaging Details: Carton Packing
Supply Ability: 100unit/week
Contact Now
Detailed Product Description
Product Name: Inserted Type Ultrasonic Flow Meter Output: Datalogger/4-20mA /OCT /RS485/RS232/GPRS
Accuracy: Reading+/- 1% Transducer Type: Insertion
Transducer Range: DN20-DN6000 Selling Units: Single Item
High Light:

non invasive ultrasonic flow meter

,

high temperature ultrasonic flow meter

High accuracy Insertion Ultrasonic Flow Meter TF1100-EI With ultrasonic flow sensor
 
Our High accuracy Insertion Ultrasonic Flow Meter can be available with 4-20mA, RS232, RS485 (Modbus) /GPRS and SD card logger outputs. The Flow Meter consists of flow calculator, and the insertion transducer to measure velocity and level at the same time.
Insertion Ultrasonic Flow Meter TF1100-EI provides abundant capabilities for accurate liquid flow measurement from outside of a pipe. It utilizes state-of-the-art technologies on ultrasonic transmission /receiving, digital signal processing and transit-time measurement. The proprietary signal quality tracking and self-adapting technologies allow system to optimally adapt to different pipe materials automatically. Due to hot-tapped mounting of insertion transducers, there is no ultrasonic compound and coupling problem; Even though the transducers are inserted into pipe wall, they do not intrude into the flow, thus, do not generate disturbance or pressure drop to the flow. The insertion (wetted) type has the advantage of long-term stability and better accuracy.
 
High accuracy Insertion Ultrasonic Flow Meter TF1100-EI With ultrasonic flow sensor Features:
 
1. Thermal energy measurement capability can be optional.
2. Wide liquid temperature range: -35℃~200℃.
3. Data logger function for insertion ultrasonic flow meter
4. Hot-tapped installation, no pipe line flow interrupted
5. For commonly used pipe materials and diameters from 20mm to over 6.0m.

6. Wide bi-directional flow range of 0.01 m/s to 12 m/s..

 

Application
 

General
● Service and maintenance

● Replacement of defective devices

● Support of commissioning process and installation

● Performance and efficiency measurement
- Capacity measurement of pumps
- Monitoring of regulating valves

- Evaluation and assessments

● Energy efficiency audits

 

Water and waste water industry - hot water, cooling water, potable water, sea water etc.)
Petrochemical industry
Chemical industry -chlorine, alcohol, acids, .thermal oils.etc
Refrigeration and air conditioning systems

Power supply- nuclear power plants, thermal & hydropower plants), heat energy boiler feed water.etc
Metallurgy and mining applications
Food , beverage and pharmaceutical industry
Mechanical engineering and plant engineering-pipeline leak detection, inspection, tracking and collection.

 
High Accuracy Transit Time Ultrasonic Flow Meter , Insertion Ultrasonic Flow Meter 0
 

Specifications:Transmitter

 

Measurement principle Ultrasonic transit-time difference correlation principle
Flow velocity range 0.01 to 12 m/s, bi-directional
Resolution 0.25mm/s
Repeatability 0.2% of reading
Accuracy ±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s
Response time 0.5s
Sensitivity 0.003m/s
Damping of displayed value 0-99s(selectable by user)
Liquid Types Supported both clean and somewhat dirty liquids with turbidity <10000 ppm
Power Supply AC: 85-265V DC: 24V/500mA
Enclosure type Wall-mounted
Degree of protection IP66 according to EN60529
Operating temperature -20℃ to +60℃
Housing material Fiberglass
Display 4 line×16 English letters LCD graphic display, backlit
Units User Configured (English and Metric)
Rate Rate and Velocity Display
Totalized gallons, ft³, barrels, lbs, liters, m³,kg
Thermal energy unit GJ,KWh can be optional
Communication 4~20mA(accuracy 0.1%),Frequency(1-9999Hz), Relay, RS232, RS485 (Modbus),Logged data

 

Specifications:Transducer

 

Degree of protection IP67 or IP68 according to EN60529
Suited Liquid Temperature Std. Temp.: -35℃~85℃
High Temp.: -35℃~150℃
Pipe diameter range DN65-6000
Transducer Size Type S Φ58*199mm
Material of transducer Stainless Steel
Cable Length Std: 10m
Temperature Sensor

Pt1000, 0 to 200℃, Clamp-on and Insertion type Accuracy: ±0.1%

 

 

Packing & Delivery

 

Inserted Type Ultrasonic Flow Meter With 4-20mA Output for clean liquid application

 

With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support. With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support.
 
High Accuracy Transit Time Ultrasonic Flow Meter , Insertion Ultrasonic Flow Meter 1High Accuracy Transit Time Ultrasonic Flow Meter , Insertion Ultrasonic Flow Meter 2
High Accuracy Transit Time Ultrasonic Flow Meter , Insertion Ultrasonic Flow Meter 3High Accuracy Transit Time Ultrasonic Flow Meter , Insertion Ultrasonic Flow Meter 4

Delivery

Inserted Type Ultrasonic Flow Meter With 4-20mA Output 

Standard meter: 3-7 days

Special meter: pls contact us

Express, by air, by sea can be optional.

Contact Details
Lanry Instruments (Shanghai) Co., Ltd.

Contact Person: Ms. Tracy Xu

Tel: 86-021-67618991

Fax: 86-021-67801625

Send your inquiry directly to us (0 / 3000)