Send Message
Lanry Instruments (Shanghai) Co., Ltd.

Lanry Instruments (Shanghai) Co., Ltd.

 

Specialize In Ultrasonic Flowmeter More Than 20 Years!

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsHandheld Ultrasonic Flow Meter

Flow Rate Calibration Ultrasonic Flow Measurement

Flow Rate Calibration Ultrasonic Flow Measurement

  • Flow Rate Calibration Ultrasonic Flow Measurement
Flow Rate Calibration Ultrasonic Flow Measurement
Product Details:
Place of Origin: China
Brand Name: Lanry
Certification: ISO9000, CE, CPA,CMC
Model Number: TF1100-CH
Payment & Shipping Terms:
Minimum Order Quantity: 1 Unit
Price: Negotiable
Packaging Details: carton packing 44X33X22cm 1PC/carton
Delivery Time: 7-10 working days
Payment Terms: T/T
Supply Ability: 1000pcs/month
Contact Now
Detailed Product Description
Flow Velocity Range: 0.01 To 12m/s, Bi-directional Type: Handheld
Response Time: 0.5s Power Supply: AC:85-265V Up To 14 Hours With Fully Charged Internal Batteries
Communication: OCT, RS232 ,Logged Data Degree Of Protection: IP68
High Light:

ultrasonic liquid flow meter

,

high temperature ultrasonic flow meter

Flow Rate Calibration Ultrasonic Flow Measurement TF1100-CH
 
Transit-time Ultrasonic Flow Meter work with method. The 14 hours battery can be recharged, The back-lit 4 lines display makes the readings more intuitive. The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges.
User can use hand to hold as well as to operate the flow meter main unit. This flexible and easy-to-use flow meter is an ideal tool to support service and maintenance activities.It can also be used for the control or even for the temporary replacement of permanently installed meters.
 
Flow Rate Calibration Ultrasonic Flow Measurement TF1100-CH​ Features:
 
1)Can be used for mobile measurement, flow rate calibration, data comparing, meters running status checking.
2)Non-invasive transducers.
3)Wide bi-directional flow range of 0.01 m/s to 12 m/s. Wide liquid temperature range: -35℃~200℃.
4)Works reliably in both clean and somewhat dirty liquids with turbidity<10000ppm.

 
Flow Rate Calibration Ultrasonic Flow Measurement Applications:
 
Chemical industry -chlorine, alcohol, acids, .thermal oils.etc
Water and waste water industry - hot water, cooling water, potable water, sea water etc.)
Petrochemical industry
Refrigeration and air conditioning systems
Food , beverage and pharmaceutical industry
Power supply- nuclear power plants, thermal & hydropower plants), heat energy boiler feed water.etc
Metallurgy and mining applications
Mechanical engineering and plant engineering-pipeline leak detection, inspection, tracking and collection.
 
General
 
● Support of commissioning process and installation
● Service and maintenance
● Replacement of defective devices
● Performance and efficiency measurement
- Evaluation and assessments
- Capacity measurement of pumps
- Monitoring of regulating valves
 
Flow Rate Calibration Ultrasonic Flow Measurement 0 
 
Specifications: Transmitter
 

Measurement principleUltrasonic transit-time difference correlation principle
Flow velocity range0.01 to 12 m/s, bi-directional
Resolution0.25mm/s
Repeatability0.2% of reading
Accuracy±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s
Response time0.5s
Sensitivity0.003m/s
Damping of displayed value0-99s(selectable by user)
Liquid Types Supportedboth clean and somewhat dirty liquids with turbidity <10000 ppm
Power SupplyAC: 85-265V Up to 14 h with fully charged internal batteries
Enclosure typeHandheld, Portable
Degree of protectionIP65 according to EN60529
Housing materialABS( UL 94HB)
Operating temperature-20℃ to +60℃
Display4 line×16 English letters LCD graphic display, backlit
UnitsUser Configured (English and Metric)
RateRate and Velocity Display

 
Specifications: Transducer
 

Degree of protectionIP65 according to EN60529.(IP67 or IP68 Upon request)
Pipe diameter range20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L
Suited Liquid TemperatureStd. Temp.: -35℃~85℃ for short periods up to 120℃
High Temp.: -35℃~200℃ for short periods up to 250℃
Transducer SizeType S 48(h)*28(w)*28(d)mm
Type M 60(h)*34(w)*33(d)mm
Type L 80(h)*40(w)*42(d)mm
Material of transducerAluminum for standard temp. sensor, and peek for high temp. sensor
Cable LengthStd: 5m

 
Data sheet download TF1100-CH transit-time handheld ultrasonic flowmet...
Manual Download TF1100-CH transit-time handheld flowmeter Manual.p...
 
Dimensional Sketches
 
Transmitter:
Flow Rate Calibration Ultrasonic Flow Measurement 1
Transducer:
 
Flow Rate Calibration Ultrasonic Flow Measurement 2
 

Packing & Delivery

 

With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support. With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support.
 
Flow Rate Calibration Ultrasonic Flow Measurement 3Flow Rate Calibration Ultrasonic Flow Measurement 4Flow Rate Calibration Ultrasonic Flow Measurement 5

Delivery

Clamp On Handheld Ultrasonic Flow Meter TF1100-CH for water and chilled water application
Standard meter: 3-7 days
Special meter: pls contact us
Express, by air, by sea can be optional.

Contact Details
Lanry Instruments (Shanghai) Co., Ltd.

Contact Person: Ms. Tracy Xu

Tel: 86-021-67618991

Fax: 86-021-67801625

Send your inquiry directly to us (0 / 3000)